SMC Sierra Monitor ProtoNode FPC-N54 User Manual

SMC Sierra Monitor ProtoNode FPC-N54
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Document Revision: 3.C
Web Configurator
Template Revision: 4
ProtoNode FPC-N54
Start-up Guide
For Interfacing ABB Products:
ACS800, ACS880, ACS880-CTDD
To Building Automation Systems:
BACnet MS/TP, BACnet/IP and SMC Cloud
APPLICABILITY & EFFECTIVITY
Explains ProtoNode hardware and installation.
The instructions are effective for the above as of February 2020.

Table of Contents

Questions and Answers:

SMC Sierra Monitor ProtoNode FPC-N54 Specifications

General IconGeneral
BrandSMC Sierra Monitor
ModelProtoNode FPC-N54
CategoryGateway
LanguageEnglish

Summary

CERTIFICATION

BTL Mark – BACnet® Testing Laboratory

The BTL Mark indicates a product has passed rigorous tests by an independent laboratory.

INTRODUCTION

ProtoNode Gateway

High-performance building automation gateway for ABB devices and BACnet.

PROTONODE SETUP

Record Identification Data

Documenting the unique part number of the ProtoNode unit.

Point Count Capacity and Registers per Device

Specifies the maximum registers a connected device can present.

Configuring Modbus Device Communications

Ensuring COM settings match between devices for communication.

INTERFACING PROTONODE TO DEVICES

Device Connections to ProtoNode

Connecting RS-485 devices to the ProtoNode's R1 port.

Wiring Field Port to RS-485 Serial Network

Connecting RS-485 network wires to the ProtoNode's R2 port.

Bias Resistors

Using DIP switches to enable bias resistors for RS-485 bus stability.

Termination Resistor

Enabling the end-of-line termination resistor for the serial trunk.

Power-Up ProtoNode

Checking power requirements and connecting power to the ProtoNode.

CONNECT THE PC TO THE PROTONODE

Connecting to the ProtoNode via Ethernet

Establishing a connection using a Cat-5 Ethernet cable.

Changing the Subnet of the Connected PC

Configuring PC's IP address and subnet mask for network communication.

CONFIGURE THE PROTONODE

Accessing the ProtoNode Web Configurator

Navigating to the ProtoNode's IP address via a web browser.

Select Profile and Set Configuration Parameters

Choosing the correct device profile and setting parameters.

Verify Device Communications

Checking LEDs for flashing to confirm communication.

Ethernet Network: Setting IP Address for the Field Network

Configuring IP address for the ProtoNode's Ethernet port.

How to Start the Installation Over: Clearing Profiles

Steps to clear profiles and restart the unit for reinstallation.

Appendix A Troubleshooting

Lost or Incorrect IP Address

Procedures to locate or correct the ProtoNode's IP address.

Viewing Diagnostic Information

Accessing diagnostic data via web browser or FieldServer Toolbox.

Checking Wiring and Settings

Verifying COM settings, LEDs, and wiring for communication issues.

LED Diagnostics for Communications Between ProtoNode and Devices

Understanding the meaning of diagnostic LEDs.

Take a FieldServer Diagnostic Capture

Methods for capturing diagnostic data for troubleshooting.

Appendix B Additional Information

Updating Firmware

Instructions for loading a new version of the firmware.

Securing ProtoNode with Passwords

Enabling password protection for the FS-GUI interface.

Factory Reset Instructions

Guidance on how to reset the FieldServer to its factory state.

Internet Browsers Not Supported

Information on unsupported web browsers.

Mounting

How to mount the ProtoNode using its DIN rail bracket.

Physical Dimension Drawing

Drive Specific QuickStart Guides

ACS800 Drive Setup

Setup instructions for FPC-N54 gateway with an ACS800 drive.

ACS800 Drive Wiring

Diagram and details for wiring the ACS800 drive to the ProtoNode.

ACS800 Modbus RTU Mappings to BACnet

Table detailing Modbus RTU to BACnet object ID mappings for ACS800.

ACS880 Drive Setup

Setup instructions for FPC-N54 gateway with an ACS880 drive.

ACS880 Drive Wiring

Diagram and details for wiring the ACS880 drive to the ProtoNode.

ACS880 Modbus RTU Mappings to BACnet

Table detailing Modbus RTU to BACnet object ID mappings for ACS880.

ACS880-CTDD Drive Setup

Setup instructions for FPC-N54 gateway with an ACS880-CTDD drive.

ACS880-CTDD Drive Wiring

Diagram and details for wiring the ACS880-CTDD drive to the ProtoNode.

ACS880-CTDD Modbus RTU Mappings to BACnet

Table detailing Modbus RTU to BACnet object ID mappings for ACS880-CTDD.

Appendix C Reference

Specifications

Technical specifications for the ProtoNode FPC-N54.

Compliance with UL Regulations

Requirements for UL compliance when operating the ProtoNode.

Appendix D Limited 2 Year Warranty