Activated Charcoal Filter (Recirculation Version)
Can be washed in the dishwasher. It must be washed when
is displayed or at least once every 4
months, or more frequently if use is particularly intense. Guaranteed to operate after washing for up to a
maximum of 5 times before requiring replacement. The Alarm signal, if it has been activated, only appears
when the Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a
later date.
• Turn the Lights and the Suction Motor off.
• Press and hold button E for 2 seconds:
• C flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• C flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press and hold button G for 2 seconds.
Changing the Filter
• Remove the comfort panel.
• Remove the Metal grease filters.
• Remove the metal filter stops from the grease filter and
clean the saturated activated charcoal odour filter.
• Replace the clean activated charcoal filter, hooking it
back up to the grease filter using the metal filter stops.
• Replace the Metal grease filters.
• Close the comfort panel.
Lighting unit
Warning: This appliance is fitted with a white LED lamp classed as 1M
according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maxi-
mum optical power emitted @439nm: 7µW. Do not look directly at the
light through optical devices (binoculars, magnifying glasses…).
• For replacement contact technical support. ("To purchase contact tech-
nical support")