Troubleshooting/Specifications
Problem Cause Correction
Engine is running, but no AC
output is available.
1. One of the circuit breakers is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Red LED light is steady. Generator is
overloaded or overheated.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. See Generator Capacity. Press
Main Reset button on control panel.
Engine runs well at no-load but
“bogs down” when loads are
connected.
1. Generator is overloaded. 1. See Generator Capacity.
Engine will not start; starts and
runs rough or shuts down when
running.
1. Starting dial is in off
position.
2. Low oil indicator light comes on. Low
oil level.
3. Dirty air cleaner.
4. Out of fuel.
5. Spark plug wire not connected to
spark plug.
6. Flooded with fuel.
1. Turn starting dial to
run
position.
2. Fill crankcase to proper level or
place generator on level surface.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Connect wire to spark plug.
6. Wait 5 minutes and re-crank engine.
Engine shuts down and CO
shutdown LED blinks red
(•• •).
1. Generator improperly located.
1. Move generator to an open,
outdoor area. Air out premises (e.g.
open windows and doors) before
reoccupying. See Carbon Monoxide
(CO) Shutdown System.
For all other issues, see a Briggs & Stratton authorized dealer.
Specifications
Rated Wattage* ........................................... 3,700
Starting Wattage** ......................................... 4,500
AC Current at 120 Volts ................................30.8 Amps
Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Phase .............................................Single Phase
Displacement .................................13.7 cu. in. (224 cc)
Spark Plug Gap ........................0.028-0.031 in. (0.7-0.8 mm)
Fuel Capacity ........................ 3.5 U.S. Gallons (13.25 Liters)
Oil Capacity ................................20 Ounces (0.6 Liters)
*Generator per PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018, Safety and Performance of
Portable Generators.
**Per Briggs & Stratton 628K.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Snapper SP4500 and is the answer not in the manual?

Snapper SP4500 Specifications

General IconGeneral
BrandSnapper
ModelSP4500
CategoryPortable Generator
LanguageEnglish

Related product manuals