EasyManua.ls Logo

socomec ATyS g M - ATYS G M Versions; Product Presentation; Specifications and Advantages; Supply Types

socomec ATyS g M
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ATySgM - 542933D - SOCOMEC
17EN
5. OPTIONAL ACCESSORIES
Auxiliary contacts Each product can take up to 2 auxiliary contact
blocks. Each accessory integrates 1 NOC auxiliary
contact (for each position I, O and II) 13091001 or
NONC for 13091011.
Characteristics: 250 VAC / 5 A maximum. The ATyS
d M includes 1x aux contact reference 1309 1001 as
standard.
Ref. : 1309 1001
Ref. : 1309 1011
Bridging bars To provide a common point on the outgoing side of
the switch (load side).
Single phase product:
Rating ≤125A : 1309
2006 Rating 160A:
1309 2016
Three phase product:
Rating ≤125A : 1309
4006 Rating 160A:
1309 4016
Terminal shrouds Protection against direct contact with terminals
or connecting parts. Other features: Perforations
allowing remote thermographic inspection without
removal. Possibility of sealing.
Ref. : 2294 4016
2 parts/ref.
Enclosure Fully dedicated to ATySM use, this
polycarbonate enclosure provides easy access
to a compact, enclosed transfer switch (HxWxD:
385x385x193mm).
Ref. : 1309 9006
Extension unit Combined with the polycarbonate enclosure, the
extension box creates extra space for routing cables
with a larger diameter.
Ref. : 1309 9007
Single phase
residential enclosure
Dedicated to the implementation of a single-phase
ATyS M, it enables easy access to a compact power
supply switching solution.
40-160A (HxWxD: 410x305x150mm).
IP41
Ref. : 1309 9056
Sealable cover. It prevents access to the configuration panel of the
ATySgM.
Three phases product:
Ref. : 1359 0000
Single phase product:
Ref. : 1359 2000
Auto-transformer For use with ATyS M in 400 VAC three-phase
applications without a distributed neutral. As the
ATyS M has a 230Vac auxilliary power supply
requirement. When no neutral connection is available
this autotransformer (400/230 VAC, 400 VA)
provides the 230 VAC required for the ATyS M to
function.
Ref. : 1599 4121
Power connection
terminals
The power connection terminals allow conversion
of the cage terminals into bolt-on type connection
terminals, enabling connection of up to two 35mm²
cables or one 70mm² cable. Each power connection
terminal is provided with separation screens.
Ref. : 1399 4017
For complete
conversion, order 3
times the reference.

Table of Contents