7.2.2. Calculation rules for the max. number of products on the Digiware BUS
The total power consumed by the equipment connected to the Digiware BUS must not exceed the power from the
24 VDC supply.
Power supply must not exceed 20 W.
Size with P15 power supply (ref: 4829 0120) delivering 15 W
For example, it is possible to use
1 DIRIS Digiware C-31 interface system (0.8W)
1 DIRIS Digiware U-3xdc (0.6W) voltage module
50 metres of cable (1.5 W)
6 DIRIS Digiware I-3xdc current modules (6 x 2 = 12W)
Total power = 15W
Size with a 24 VDC power supply delivering a maximum of 20 W
For example, it is possible to use
1 DIRIS Digiware C-31 interface system (0.8W)
1 DIRIS Digiware U-3xdc (0.6W) voltage module
50 metres of cable (1.5 W)
8 DIRIS Digiware I-3x current modules (8 x 2 = 16W)
Total power = 19W
or
1 DIRIS Digiware D-50 (2W) display
1 DIRIS Digiware U-3xdc (0.6W) voltage module
50 metres of cable (1.5 W)
8 DIRIS Digiware I-3x current modules (8 x 2 = 16W)
Total power = 20W
7.2.3. Digiware bus repeater
Whenever the power consumption is higher than 20 W or the distance is greater than 100 m, a DIRIS Digiware
C-32 repeater is required.
In a DIRIS Digiware system, a maximum of 2 repeaters may be used.
DIRIS Digiware C-32
repeater
Part number
4829 0103