7
3.5Installation Position
ME3000SP should be vertically mounted (to ensure fast heat dissipation), please choose a position without
direct sunlight / snow accumulation to install ME3000SP.
Fig. 4 Installation Position of ME3000SP
3.6Mount ME3000SP
Step 1: Put the mounting bracket properly on the wall, mark these 8 drill holes using a marker pen. Drill 8
holes (drill bit 6mm) on the wall.
Step 2: Insert the expansion screw vertically into the hole, note the insertion depth. (not too shallow or too
deep)
Step 3: Fix the mounting bracket on the wall using bolts & flat washers.
Step 4: Put ME3000SP on the mounting bracket.
Step 5: Earth ME3000SP using the grounding hole on the heat sink.
Step 6: OPTIONAL: you can lock ME 3000SP to the mounting bracket.