6.Operation
6.1Double Check
Please double check the following before operation.
1. ME3000SP is firmly fastened to the mounting bracket on the wall;
2. The polarity of battery wires is correct, battery wires are firmly connected;
3. DC isolator is correctly connected between battery & ME3000SP, DC isolator: OFF;
4. GRID / LOAD cables are firmly / correctly connected;
5. AC circuit breaker is correctly connected between ME3000SP GRID port & GRID, AC circuit breaker:
OFF;
6. AC contactor (if present) is correctly connected (fig. 12);
7. For lithium battery, please ensure that the communication cable has been correctly connected;
8. For the lead-acid battery, please ensure that the NTC wire has been correctly connected.
6.2First Time Setup (IMPORTANT!)
IMPORTANT: PLEASE FOLLOW THE FOLLOWING PROCEDURE to switch ON ME3000SP
1. Make sure theres no power generation in ME3000SPs phase. (Turn OFF PV inverter.)
2. Switch on the battery. Turn ON DC isolator between battery & ME3000SP.
3. Turn ON AC circuit breaker between ME3000SP GRID port & GRID.
4. ME3000SP should start to operate now.
You need to set the following parameters before ME3000SP start to operate.
1)Set system time
8)*Set min discharge voltage
2)Set country
9)*Set max discharge current
3)Select battery type
10)*Set min protect voltage
4)*Set battery capacity
11)*Set discharge depth
5)*Set max charge voltage
12)*Set empty discharge voltage
6)*Set max charge current
13)*Set full charge voltage
7)*Set max protect voltage
Note: 4) * to 13) * settings are only for DEFAULT battery type.
1)Set system time
Set the system time for the inverter.
2)Set country
Set up the safety regulation country that meets the current use conditions and requirements. When country
setting is complete, “Set battery type” will pop up.
Code
Country
Code
Country
Code
Country
00
Germany VDE4105
14
Germany VDE0126
28
Brazil
01
CEI-021 Internal
15
CEI-016 Italia
29
Slovakia VSD
02
Australia
16
UK G98
30
Slovakia SSE
03
SpainRD1699
17
Greece island
31
Slovakia ZSD
04
Turkey
18
EU EN50438
32
CEI0-21 In Areti
05
Denmark
19
IEC EN61727
33
Ukraine
06
Greece Continent
20
Korea
34
Brazil LV
07
Netherland
21
Sweden
35
Mexio LV
08
Belgium
22
Europe General
36
FAR Arrete32
09
UK G99
23
CEI-021 External
37
Denmark TR322
10
China
24
Cyprus
38
Wide-Range-60HZ