10.
The inverter is configured by default to LAN.
a. Make sure the ON/OFF/P switch is OFF.
b. Turn ON the AC to the inverter by turning ON the circuit breaker on the main
distribution panel.
c.
Configure the connection as described in
Communication
on page 42.
NOTE
If your network has a firewall, you may need to configure it to enable
the connection to the following address:
Destination Address: prodssl.solaredge.com
TCP Port: 443 (for incoming and outgoing data)
11. Verify the connection, as described in
Verifying the Connection
on page 54.
Verifying the Connection
After connecting and configuring a communication option, perform the following
steps to check that the connection to the Monitoring platform has been successfully
established.
1. Access SetApp and selectCommissioning >Status.
2. In the Summary section, under Server Comm., make sure S_OK is displayed
together with the selected communication option.
3.
Scroll down to the Communication section and check that the communication
options are as required.
Single Phase Energy Hub Inverter MAN-01-00812-1.1
54 Verifying the Connection