Chapter 3: Installing the Inverter
SolarEdge Installation Guide – MAN-01-00057-2.2
LCD LEDs: Three LEDs indicate the following inverter statuses (see Figure 4):
On - The inverter is producing power.
Blinking - Standby mode. The inverter is in Standby mode until
its working voltage is reached. The inverter then enters
Production mode and produces power.
Off - The inverter is not producing power. This may be during
Night mode, when the inverter ON/OFF switch is OFF or when
an error occurs.
Module communication
and inverter shutdown
Blinking:
Monitoring information is being received from a power
optimizer.
The inverter is being shut down.
On - There is an error. Refer to Appendix A: Errors and
Troubleshooting on page 50 for more information.
Blinking - The inverter is being shut down.
All LEDs are on while the inverter is being configured.
Figure 4: Inverter front view
AC output
AC cable external gauge:
Single phase inverters: PG21 (9-16mm diameter)
Three phase inverters: M32 (15-21mm diameter)
DC inputs: For connection of the PV installation
CAUTION:
Do not remove the six screws on the DC metal panel as it may harm the inverter sealing and void
the warranty.