Chapter 5: User Interface
SolarEdge Installation Guide MAN-01-00057-2.2
37
Main Inverter Status
V a c [ v ] V d c [ v ] P a c [ w ]
2 4 0 . 7 3 7 1 . 9 3 2 1 0 . 0
F a c [ H z ] OPs _ O k T e m p
5 0 . 0 1 1 2 8 . 2
Vac [V: The AC output voltage.
Vdc [V]: The DC input voltage.
Pac [W]: The AC output power.
Fac[Hz]: The AC output frequency.
OPs_Ok: Number of optimizers sending telemetries (indicating that they are paired)
Temp [C or F]: The inverter’s heat sink temperature
Energy Meter Status
Displays the total energy produced during the last day, month, year and since inverter installation.
D a y [ W h ] : 0 . 0
M o n t h [ K W h ] : 0 . 0
Y e a r [ K W h ] : 0 . 0
T o t a l [ K W h ] : 0 . 0
NOTE:
This data is accumulated according to an internal real-time clock.
Telemetry Status
This window displays the last power optimizer telemetry received. The display changes as each power
optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for some time in order
to observe the power optimizers report process.
M o d u l e : 0 0 0 C 1 E D 9 - 03
E n e r g y [ W h ] : 0
V d c _ O [ V ] : 40.5
V d c _ I [ V ] : 2 9 . 5
Module#: Power optimizer serial number
Energy: power optimizer energy
Vdc_O: Power optimizer output voltage
Vdc_I: Power optimizer input voltage (module voltage)
ID Status
This window displays the inverter software version and the country to which the inverter is configured.
ID: # # # # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 2 . 0 1 1 1
C o u n t r y : Uni t e d K i n g d o m

Table of Contents