Power Control Status
Appears only if Power Control is enabled.
P C o n t r o l : G E R
P e a k P o w e r : 0 %
P F : + 1 . 0 0
A C P o w e r : 0 W
P Control: Specifies the country according to which power control is done.
Peak Power: Specifies the ratio between the power the inverter can output and the inverter’s
maximum AC power. If active power is limited (either using the RRCR option or using the Active
Power Limit option), the limit will be displayed here.
PF: Power Factor. Specifies the CosPhi corresponding to the ratio between active and reactive power
AC Power: Specifies the AC power that the inverter is currently producing.
For more information, refer to the Power Control Application Note, available on the SolarEdge website at
http://www.solaredge.com/files/pdfs/application_note_power_control_configuration.pdf.