2
3
2 Safety
2.1 Safety Instructions
For safety reasons, installers are responsible for familiarizing themselves with the
contents of this manual and all warnings before performing installation.
2.1.1 General Safety Precautions
Observe the following precautions:
·
Risks of explosion
– Do not subject the battery to strong impacts.
– Do not crush or puncture the battery.
– Do not dispose of the battery in a re.
· Risks of re
– Do not expose the battery to temperatures in excess of 55°C.
– Do not place the battery near a heat source, such as a replace.
– Do not expose the battery to direct sunlight.
– Do not allow the battery connectors to touch conductive objects such as
wires.
· Risks of electric shock
– Do not disassemble the battery.
– Do not touch the battery with wet hands.
– Do not expose the battery to moisture or liquids.
– Keep the battery away from children and animals.
· Risks of damage to the battery
– Do not allow the battery to get in contact with liquids.
– Do not subject the battery to high pressures.
– Do not place any objects on top of the battery.
T-BAT SYS-HV can only be used in the household energy eld. It is not allowed to
be used in other industries, such as the medical equipment industry and
automotive application industry.
WARNING!
Please don't crush or impact the battery, and always dispose it
according to the safety regulation.
2.1.2 Explanation of Symbols
This section gives an explanation of all the symbols shown on the T-BAT system
and on the warning label.
CAUTION!
If the battery is not installed within one month after receiving the battery,
the battery must be charged till the SOC is more than 50% for maintains.
Lithium ion Rechargeable Battery System
Product Name: T-BAT SYS-HV
Max.Charge/Discharge Current: 35A
Charging Temperature: 0~+55℃
Storage Temperature: -20~+55℃
SolaX Power Network Technology (Zhejiang) Co., Ltd
ADD: No.288 Shizhu Road, Tonglu Economic Development Zone,
Dongxing District, Tonglu City, Zhejiang Province, China.
TEL: +86 571 5626 0011 E-mail: info@solaxpower.com
www.solaxpower.com
Ma de in C h ina
612.0157 9. 01
Rated Capacity: 50Ah
Model No./Nominal Voltage/Rated Capacity
T-BAT H 5.8/115.2Vdc/5.8kWh IFpP/41/150/102/M/-20+50/90
T-BAT H 11.5/230.4Vdc/11.5kWh IFpP/41/150/102/M/-20+50/90
T-BAT H 17.3/345.6Vdc/17.3kWh IFpP/41/150/102/M/-20+50/90
T-BAT H 23.0/460.8Vdc/23.0kWh IFpP/41/150/102/M/-20+50/90
SN: