Electrical Connections
55
waterproof distribution box
B
CT connection with RJ45 connector
For CT connection with RJ45 connector, connect the A terminal to the Meter/
CT port of the inverter
,
tighten the waterproof screw and connect the B
terminal to the RJ45 coupler..
Note!
When installing, pay attention to water resistance. All the con-
nected parts of CT must be placed into the distribution cabinet.
• Do not place the CT on the N wire or ground wire.
• Do not put CT on the N line and L line at the same time.
• Do not place the CT on the side where the arrow points to the
inverter.
• Do not place the CT on non-insulated wires.
• After CT is connected, prevent the CT clip from falling o.
• It is recommended to wrap the CT clip with insulating tape.
For CT connection without RJ45 connector, insert one side of the finished
cable and the waterproof connectors with RJ45 into the Meter/CT port of the
inverter, tighten the waterproof screw and insert the other side of the RJ45
terminal into the CT connection.
CT connection without RJ45 connector