■ EPS load requirements
Warning!
Ensure that the EPS load rated power is within the EPS rated
output power range, otherwise, the inverter will report an over-
load warning.
When overload occurs, adjust the load power to make sure it
is within the EPS rated output power range, and the inverter will
automatically return to normal operation.
For non-linear loads, ensure that the inrush current power is
within the EPS rated output power range.
The following table shows some common loads for your reference.
Note: Check with the manufacturer for high-power inductive loads.
Content
Power
Common
equipment
Instance
Start Rated Equipment Start Rated
Resistive
load
X 1 X 1
Incandescent
lamp
100W
Incandescent
lamp
100VA
(W)
100VA
(W)
Inductive
load
X 3~5 X 2
Fan Fridge
150W
Fridge
450-
750VA
(W)
300VA
(W)