46
Electrical Connection
Figure 8-9 Stripping the EPS (off-grid) cable
Step 2: Disassemble the AC protective cover (part N) as shown below. Remove the
sealing plug. Please note that keep the sealing plug in the hole if it is not in use.
Remove
Figure 8-10 Disassembling the AC protective cover
Step 3: Thread the Grid and EPS (off-grid) cable through the swivel nut and the AC
protective cover enclosure in sequence.
Figure 8-11 Threading the grid cable
Step 4: Insert the conductors L1, L2, L3, N, and the grounding conductor of Grid cable
and the conductors L1, L2, L3, N of EPS (off-grid) cable into the ferrules (part
I). Use a crimping tool for ferrules to crimp it. Make sure the conductors are
correctly assigned and firmly seated in the ferrules.