60
Electrical Connection
1 2 3 4 5 6 7 8
1 8
1) White with orange stripes
2) Orange
3) White with green stripes
4) Blue
5) White with blue stripes
6) Green
7) White with brown stripes
8) Brown
Figure 8-36 Crimping the network cable
Step 3: Install the network cable of the crimped RJ45 terminal to BMS terminal according
to the labeling.
1
2
BMS
Click!
Figure 8-37 Connecting to BMS terminal
8.6.3 Meter/CT Connection
The inverter should work with an electric meter or current transformer (CT for short) to
monitor household electricity usage. The electricity meter or CT can transmit the relevant
electricity data to the inverter or platform.
CAUTION!
• Smart meters must be authorized by our company. Unauthorized meter may be
incompatible with the inverter, thereby resulting in inverter damage and working
mode malfunction. SolaX will not be responsible for the impact caused by the use of
other appliances.
NOTICE!
• For detailed meter/CT connection, see "15.6 Meter/CT Connection Scenarios".