14
b The inverter must be installed in a well ventilated environment to ensure good heat dissipation. .
c The inverter must be free from direct exposure to sunlight rain and snow to extend its service. , ,
life. It is recommended that the inverter be installed in a sheltered place. If no shelter is
available, build an awning, as shown in Figure 4.3.
Figure 4 3 Installation environment with awning unit mm. ( : )
Carrier Requirements
Installation Space Requirements
a It is recommended that the inverter be installed at eye level to facilitate operation and.
maintenance.
b Reserve enough clearance around the inverter to ensure sufficient space for installation.
and heat dissipation, as shown in Figure 4.4.
a The carrier where the inverter is installed must be fire-proof Do not install the inverter on. .
flammable building materials.
b The wall must be solid enough to bear the weight of the inverter. .
c Do not install the inverter on a wall made of gypsum boards or similar materials with weak.
sound insulation to avoid noise disturbance in a residential area.
the front view
Awning
the lateral view
≥500
≥1000