EasyManua.ls Logo

SOMFY Axovia 220A User Manual

SOMFY Axovia 220A
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Notice d’installation
Guia de instalacion
Installation guide
Montagehandleiding
220 A
Ref: 1 216 012 V5
Question and Answer IconNeed help?

Do you have a question about the SOMFY Axovia 220A and is the answer not in the manual?

SOMFY Axovia 220A Specifications

General IconGeneral
Max Door Weight200 kg per leaf
Control SystemIntegrated electronic control unit
Motor Voltage24V DC
Operating Temperature-20°C to +60°C
Protection RatingIP44
Maximum Power150W
Power Supply230V AC
Max Gate Length2.0 m per leaf
Safety FeaturesObstacle detection

Summary

Safety Recommendations

Safety Guidelines and Precautions

Follow all safety guidelines regarding electrical, operational, child, and maintenance precautions.

Kit Composition

Assembly Process

Gate Measurement and Marking

Measure gate dimensions, identify distances, and mark the AM axis on the pillar.

Electrical Connections

Motor Connections to Control Unit

Connect motors M1 and M2 to the designated terminals on the control unit.

Adjustment Process

Remote Control Memorization

Programming

Gate Travel and Mode Programming

Memorize gate travel and set operating modes (sequential/semi-auto), then secure the settings.

Troubleshooting

L1 Not Lighting Up

Check mains supply, power cable, and fuse if LED L1 does not illuminate on power-up.

L3 Permanently On

Diagnose photocell faults (alignment, cables, power, mode) if LED L3 remains constantly lit.

Motor Start or Direction Issues

Verify motor connections, extension cables, and connector colors for proper motor operation.