1.Code Illustration
CN□□-R C□□
Display digit
:
6
:
6 digits
Control output:R:Relay output S:Solid state relay output
CN Series multi-function counter
□□
Alarm output:B:one C:two
*24V power supply could be ordered
Communication function:0:without communication 8:RS485 communication
Power supply:Blank:100-240VAC/DC F:24VDC power supply
Dimension(mm):4:48H×48W×101L 7:72H×72W×100L 8:48H×96W×100L
80:80H×160W×102L
For your safety, please read the below content carefully before you use the meter !
Safe Caution
Please comply with the below important points:
Warning An accident may happen if the operation does not comply with the instruction.
Notice An operation that does not comply with the instruction may lead to product damage.
The instruction of the symbol in the manual is as below:
An accident danger may happen in a special condition.
Warning
1. A safety protection equipment must be installed or please contact with us for the relative information if the product is used under
the circumstance such as nuclear control, medical treatment equipment ,automobile, train, airplane, aviation, entertainment or safety
equipment, etc. Otherwise, it may cause serious loss, fire or person injury.
2. Apanel must be installed, otherwise it may cause creepage (leakage).
3. Do not touch wire connectors when the power is on, otherwise you may get an electric shock.
4. Do not dismantle or modify the product, If you have to do so, please contact with us first. Otherwise it may cause electric shock
and fire.
5. Please check the connection number while you connect the power supply wire or input signal, otherwise it may cause fire.
.
Caution
1. This product cannot be used outdoors. Otherwise the working life of the product will become shorter, or an electric shock accident
may happen.
2. When you connect wire to the power input connector or signal input connectors, the moment of the No.20AWG (0.50 mm2) scrwew
tweaked to the connector is 0.74n.m-0.9n.m. Otherwise the connectors may be damaged or get fire.
3. Please comply with the rated specifications. Otherwise it may cause fire after the working life of the product becomes shorter.
4. Do not use water or oil base cleaner to clean the product. Otherwise it may cause electric shock or fire, and damage the product.
5. This product should be avoid working under the circumstance that is flammable, explosive, moist, under sunshine, heat radiation and
vibration.
6. In this unit it must not have dust or deposit, otherwise it may cause fire or mechanical malfunction.
7. Do not use gasoline, chemical solvent to clean the cover of the product because such solvent can damage it. Please use some soft
cloth with water or alcohol to clean the plastic cover.
M Meter/Yardconvertfunction
:
Meter / Yard switch function
CN Series Multi-function counter
CN Series Multi-function Counter User’s Manual
KKCNE01A-1
Features:
⊙Max counting speed can reach 10KCPS
⊙Coefficient be settable among 0.00001~999999
⊙Universal input.“NPN”or “PNP”is selected by software
⊙At most two loops of alarm for counting/length counting
one loop of alarm for batch counting
⊙
⊙
With RS485 communication function ,standard Modbus
RTU protocol
⊙Can be applied to the counting/controlling in the field of
light industry、machinery、packing、food industry ,etc.