TROUBLESHOOTING:
Programming:
Yo u c omput e r do e s n o t h a ve a serial port but you do have a USB port:
•Purchase an IO Gear USB to serial port adapter.
•For installation procedures, please visit the Navigator K2 area of our website.
Yo ur Navigator K2 does not communicate with your computer:
•Ensure the programming cable is connected at both ends.
•Ensure that the K2 is plugged into the selected COM port. You can use the auto detect
feature in the Navigator Manager software as well. Select Options then Set COM Port
from the menu list at the top. Press the Auto Detect button. Your computer should
detect and select the proper COM port. Press OK when done.
For all questions related to the Navigator Manager software, please refer to the software
manual. This manual is downloadable from the Sonance website (www.sonance.com).
Operations:
Yo ur Navigator K2 does not respond or appears to not be powered:
•Ensure that the unit is not in the powered-down state (press any button and you
should see the keypad light up).
•Ensure that the wiring is connected properly at both ends (including pin-out).
•Ensure that the device providing power (such as a Navigator Harbor) is on .
Yo ur Navigator K2 is not controlling your components:
•Ensure that the K2 is properly connected and powered (see above).
•Ensure that the K2 IR receiver is not being saturated with IR noise (sunlight, plasma,
compact fluorescent lights, …).
The Off button illumination changes from red to orange in the presence of IR
signals (default). If the Off button is continually orange it could indicate the
presence of IR noise. In this case, consider moving the keypad to another
location or disabling its IR receiver and using a separate IR receiver located
somewhere else in the room that isnt subject to IR interference.
•Ensure that signal is coming out of your Navigator K2 keypad (some devices, such as the
Navigator Harbor,have a talk-back LED that blinks when IR signals are present on the line).
If no signal is coming out, the problem is potentially improper, wiring or no
loaded program. See notes above.
If signals are present, verify that the IR codes loaded into the remote control are the
proper codes and that they were learned correctly.
•Ensure that the IR emitter(s) is connected properly and that it is placed properly on
your equipment.
FOR ALL OTHER KEYPADS,
COPY THE WIRE SET UP
AS SHOWN BELOW.
ROOM
1
(GREATROOM)
ROOM
2
*
*
*
SPEAKER RELAY SPEAKER RELAY
Diagram 2
SONANCE CATEGORY 5 CABLE
SONANCE CATEGORY 5 CABLE
SONANCE CATEGORY 5 CABLE
SYSTEM CONFIGURATION EXAMPLE: 2-ZONE IR CONFIGURATION (WITH A CONNECTING BLOCK)
FIGURE 4
FIGURE 3 SYSTEM CONFIGURATION EXAMPLE:
MULTI-ZONE SYSTEM (WITH A DAB1)