— 11 —
5-3. TUNER SECTION
Switch Location
VOLUME : MAX
MEGA BASS : OFF
PRESET SOUND MODE : OFF
Setting :
FUNCTION switch : RADIO
BAND : MW
Signal generator
Setting :
FUNCTION switch : RADIO
BAND : FM
Signal generator
Setting :
FUNCTION switch : RADIO
BAND : SW1/SW2
FINE TUNING knob : mechanical mid
0 dB = 1 µV
Repeat the procedures in each adjustment several times for the
maximum level meter indication.
The frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
FM SECTION
( ) : Saudi Arabia model
[ ] : AEP model
< > : Italian model
Adjustment Location : Main board (See page 13)
Put the lead-wire
antenna close to
the set.
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
MW RF signal
generator
0.01
µ
F
FM RF signal
generator
telescopic
antenna
input
75kHz (100%) amplitude modulation
by 1kHz signal.
Output level : as low as possible
32
set
+
level mete
r
J301 (phones)
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2 86.5 MHz (87.35 MHz )[87.0 MHz]<87.35MHz>
CT2 109.5 MHz (107.8 MHz)[108.3 MHz]<108.25 MHz>
MW SECTION
SW SECTION
set
AM rf signal
generator
telescopic antenn
a
input
10 pF
30% amplitude modulation by 400 Hz
signal output level : as low as possible
32
set
+
level mete
r
J301 (phones)
SW1 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L5 CT5
2.2 MHz 7.3 MHz
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L6 CT6
2.2 MHz 7.3 MHz
SW2 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L7 CT9
6.8 MHz 22.5 MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L8 CT10
6.8 MHz 22.5 MHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1 10.7 MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 86.5 MHz(87.35 MHz )[87.0 MHz]<87.35 MHz>
CT1 109.5 MHz(108.25 MHz )[108.3 MHz]<108.25 MHz>
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2 455 kHz
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 620 kHz
CT3 1,400 kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4 520 kHz (516 kHz)<516 kHz>
CT4 1,680 kHz (1,630 kHz)<1,630 kHz>