5-28
16. CCD Defect Compensation Check
Mode STILL
Subject Clear chart
(25 cm from the front of the lens)
(Note)
Measurement Point Display data of page: 6, address: 55
Measuring Instrument Adjustment remote commander
Specified Value 00
Note 1: Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2: Any subject other than the clear chart should not be in the screen.
Checking method:
1) Turn the power of the unit OFF and then ON.
2) Wait until the camera picture appear on the screen.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: F, address: B3, set data: 80, and press the PAUSE
button of the adjustment remote commander.
5) Select page: 5, address: F1, and set data: FF.
6) Select page: 6, address: 01, set data: 87, and press the PAUSE
button.
7) Select page: 6, address: 02, and check that the data changes to
“01”.
8) Select page: 6, address: 55, and check that the data is “00”. (If
the data is other than “00”, white defect compensation has
errors.)
9) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
10) Select page: E, address: 52, after noting down the data, set
data: 50, and press the PAUSE button.
11) Select page: F, address: AF, after noting down the data, set
data: A5, and press the PAUSE button.
12) Select page: 6, address: 2C, and set data: 01.
13) Select page: 6, address: 93, and set data: A0.
14) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
15) Select page: 6, address: 6C, and set data: 01.
16) Select page: 6, address: 01, set data: 89, and press the PAUSE
button.
17) Select page: 6, address: 02, and check that the data changes to
“01”.
18) Select page: 6, address: 55, and check that the data is “00”. (If
the data is other than “00”, black defect compensation has
errors.)
Processing after Completing Adjustments:
1) Select page: E, address: 52, set the data noted down at step
10), and press the PAUSE button.
2) Select page: F, address: B3, set data: 20, and press the PAUSE
button.
3) Select page: F, address: AF, set the data noted down at step
11), and press the PAUSE button.
4) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 2C, and set data: 00.
6) Select page: 6, address: 6C, and set data: 00.
7) Select page: 6, address: 93, and set data: 00.
8) Select page: 5, address: F1, and set data: 00.
9) Select page: 0, address: 01, and set data: 00.
Downloaded from: https://www.usersmanualguide.com/