DSC-F717
6-24
14. Auto White Balance 5800K Standard Data Input 3
RadarWRadarWRadarW
Adjust the white balance standard data at 5800K.
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter Filter C14 for color temperature
correction
Adjustment Page F
Adjustment Address 98 to 9B, 9E, 9F
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 2”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 5800K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data Procedure
1
“Auto White Balance 5800K
Standard Data Input 2” is
completed.
26 370C
3 6 01 A5 Press PAUSE button. (Note 4)
46 02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
F, address: 98 to 9B and 9E to 9F.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2
Perform “Auto White
Balance 5800K Check 1”.
13. Auto White Balance 5800K Standard Data Input 2
RadarWRadarWRadarW
Adjust the white balance standard data at 5800K.
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter Filter C14 for color temperature
correction
Adjustment Page F
Adjustment Address 92 to 97
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 1”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 5800K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data Procedure
1
“Auto White Balance 5800K
Standard Data Input 1” is
completed.
26 370A
3 6 01 A5 Press PAUSE button. (Note 4)
46 02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
F, address: 92 to 97.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2
Perform “Auto White
Balance 5800K Standard
Data Input 3”.