EasyManua.ls Logo

Sony DSC-F717 - Auto White Balance 5800 K Check 1

Sony DSC-F717
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DSC-F717
6-25
Order Page Address Data Procedure
21 0 03 04
22 1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
23 0 03 05
24 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
25 0 03 2E
26 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
27 0 03 2F
28 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2
Perform “Auto White
Balance 5800K Check 2”.
15. Auto White Balance 5800K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter Filter C14 for color temperature
correction
Measurement Point Displayed data of Page: 1 (Note 3)
Measuring Instrument Adjusting remote commander
Specified Value R ratio: 2910 to 2D10
B ratio: 5BE0 to 5FE0
R-Y level data: 0076 to 0082
B-Y level data: 0078 to 0084
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 3”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data Procedure
1
Auto White Balance 5800K
Standard Data Input 3” is
completed.
2 6 37 13
36 B603
4 6 01 11 Press PAUSE button.
56 38
Check the data changes to
“01”.
6 6 01 C3 Press PAUSE button.
76 02
Check the data changes to
“01”.
8 0 03 04
91
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
10 0 03 05
11 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
12 0 03 2C
13 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
14 0 03 2D
15 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
16 6 01 00 Press PAUSE button.
17 6 B6 00
18 6 37 14
19 6 01 3F Press PAUSE button.
20 6 02
Check the data changes to
“01”.

Table of Contents