DSC-F717
6-25
Order Page Address Data Procedure
21 0 03 04
22 1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
23 0 03 05
24 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
25 0 03 2E
26 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
27 0 03 2F
28 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2
Perform “Auto White
Balance 5800K Check 2”.
15. Auto White Balance 5800K Check 1
RadarW
RadarW
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter Filter C14 for color temperature
correction
Measurement Point Displayed data of Page: 1 (Note 3)
Measuring Instrument Adjusting remote commander
Specified Value R ratio: 2910 to 2D10
B ratio: 5BE0 to 5FE0
R-Y level data: 0076 to 0082
B-Y level data: 0078 to 0084
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 3”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data Procedure
1
“Auto White Balance 5800K
Standard Data Input 3” is
completed.
2 6 37 13
36 B603
4 6 01 11 Press PAUSE button.
56 38
Check the data changes to
“01”.
6 6 01 C3 Press PAUSE button.
76 02
Check the data changes to
“01”.
8 0 03 04
91
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
10 0 03 05
11 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
12 0 03 2C
13 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
14 0 03 2D
15 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
16 6 01 00 Press PAUSE button.
17 6 B6 00
18 6 37 14
19 6 01 3F Press PAUSE button.
20 6 02
Check the data changes to
“01”.