EasyManua.ls Logo

Sony DSC-F717 - Auto White Balance 3200 K Check 1

Sony DSC-F717
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DSC-F717
6-27
18. Auto White Balance 3200K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point Displayed data of Page: 1 (Note 3)
Measuring Instrument Adjusting remote commander
Specified Value R ratio: 3E00 to 4200
B ratio: 3E00 to 4200
R-Y level data: 007E to 0082
B-Y level data: 007E to 0082
Note 1: Perform this check after “Auto White Balance 5800K
Check 3” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data Procedure
1
Auto White Balance 5800K
Check 3” is completed.
26 370D
36 B603
4 6 01 11 Press PAUSE button.
56 38
Check the data changes to
“01”.
6 6 01 C1 Press PAUSE button.
76 02
Check the data changes to
“01”.
8 0 03 04
91
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
10 0 03 05
11 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
12 0 03 2C
13 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
14 0 03 2D
15 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
16 6 01 00 Press PAUSE button.
17 6 B6 00
18 6 37 0E
19 6 01 0F Press PAUSE button.
20 6 02
Check the data changes to
“01”.
21 0 03 04
Order Page Address Data Procedure
22 1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
23 0 03 05
24 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
25 0 03 2E
26 1
Check that the R-Y level data
(Note 3) satisfied the
specified value.
27 0 03 2F
28 1
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2
Perform “Auto White
Balance 3200K Check 2”.

Table of Contents