RadarW
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point Displayed data of page: 6,
address: 55
Measuring Instrument Adjusting remote commander
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3: Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2 E 65 Note down the data.
3 E 65 4C Press PAUSE button.
46 2C01
5 6 90 00
6 6 91 03
7 6 92 00
8 6 93 00
9 6 01 79 Press PAUSE button.
10 6 30 08
11 6 07
Check the data changes to
“01”.
12 6 01 8D Press PAUSE button.
13 6 02
Check the data changes to
“01”.
14
655
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
15 6 01 00 Press PAUSE button.
16 E 65 5A Press PAUSE button.
17 6 01 89 Press PAUSE button.
18 6 02
Check the data changes to
“01”.
19 6 55
Check the data.
00: Normal
01 to FF: Defective
Note 4: If the data is “00” at the check in this adjustment method
order #14, skip the orders from #15 to #19, and go for-
ward to “Processing after Completing Adjustment.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
26 2C00
3 6 30 00
4 6 91 00
5E 65
Set data noted down at step
2, and press PAUSE button.
6
Release the data setting
performed at step 1.
(Refer to page 6-14)