Chapter 16 Engineering Setup
252
Setup Relating to Operations From the Control Panel
3
To confirm a source address selected in step 2, press [Source Set] to
confirm a destination address press [Destination Set], and to confirm a
level press [Level Set].
This confirms the selection, which is reflected in the status area.
To set a link table
For the link selected in the External Bus Link menu, make the settings as
follows.
1
In the Panel>Config>External Bus Link>Link Matrix Adjust menu, press
[Link Table Adjust].
The Link Table Adjust menu appears.
The status area lists the status of the currently selected link, combinations
of video signals and sources, and the sources that can be selected.
2
Using any of the following methods, select the switcher cross-point button
and the matrix source to be linked to the button.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
3
To confirm the matrix source selection made in step 2, press [Link Source
Set].
This confirms the selection, which is reflected in the status area.
4
As required, repeat steps 2 and 3 to select the matrix sources to be linked
to other cross-point buttons.
To initialize the set links
Press [Init Link Table].
A confirmation message appears.
Press [Yes].
The links set using the above procedure are initialized to the default settings,
and this is reflected in the status area.
3 Destination Destination start address 1 to 897
4 Level Level 1 to 8
Knob Parameter Adjustment Setting values
Knob Parameter Adjustment Setting values
1 Main No Switcher cross-point button 1 to 128
2 Source No Matrix source selection 1 to 128