271Setup Relating to Operations From the Control Panel
Chapter 16 Engineering Setup
Assigning a function to a memory recall button in the utility/
shotbox control block
Use the following procedure.
1
In the Prefs/Utility menu, press [Utility Module Assign].
The Prefs/Utility>Utility Module Assign menu appears. The status area
shows the settings in the utility/shotbox control block.
2
Using any of the following methods, select the button to be assigned.
Press directly on the list.
Press the arrow keys to scroll the reverse video cursor.
Turn the knobs.
3
In the <Action> group, select the function you want to assign.
Menu Shortcut: Assign a frequently used menu to be recalled (menu
shortcut).
Utility Command: Assign a function enable/disable or similar operation
(utility command).
Shotbox Recall: Assign a shotbox register recall.
4
Depending on the selection in step 3, make the following settings.
When Menu Shortcut is selected: For the subsequent operations, see the
next item “Assigning a menu shortcut to a memory recall button in the
utility/shotbox control block” (page 274).
When Utility Command is selected: A list of commands appears on the
right of the status area; using any of the following methods, select the
command you want to assign.
• Press directly on the list.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
When Shotbox Recall is selected: Turn the knob to select the shotbox
register you want to assign.
Knob Parameter Adjustment Setting values
1 Bank Bank selection 1 to 4
2 Button No Control block button selection 1 to 24
Knob Parameter Adjustment Setting values
3 Command Utility command selection 1 to ...
Knob Parameter Adjustment Setting values
3 Shotbox Shotbox register selection 1 to 99