Chapter 16 Engineering Setup
272
Setup Relating to Operations From the Control Panel
5
Press [Action Set].
This assigns the selected action, which is reflected in the status area.
In the utility/shotbox control block, the assigned button lights orange.
If a shotbox register was assigned, the register name appears.
To cancel an assignment
After selecting the relevant button, press [Clear].
List of utility commands and memory recall button status
The following table shows the utility commands that can be assigned to
memory recall buttons.
Command name
a)
Function Button status
Lit green Lit orange
SWR Remote1 Enbl
|
SWR Remote4 Enbl
Switcher Remote 1 enabled/disabled
|
Switcher Remote 4 enabled/disabled
Enabled Disabled
DME1 Editor Port Enbl DME1 editor port enabled/disabled Enabled Disabled
DME2 Editor Port Enbl DME2 editor port enabled/disabled Enabled Disabled
2nd System Enbl (Dual Simul Mode) Second system
enabled/disabled
Enabled Disabled
ME1 PGM1 ST
|
ME1 PGM4 ST
M/E-1 PGM1 output safe title on/off
|
M/E-1 PGM4 output safe title on/off
On Off
ME1 PVW ST M/E-1 preview output safe title on/off On Off
ME1 Clean ST M/E-1 clean output safe title on/off On Off
ME1 K-PVW ST M/E-1 key preview output safe title on/
off
On Off
ME2 PGM1 ST
|
ME2 PGM4 ST
M/E-2 PGM1 output safe title on/off
|
M/E-2 PGM4 output safe title on/off
On Off
ME2 PVW ST M/E-2 preview output safe title on/off On Off
ME2 Clean ST M/E-2 clean output safe title on/off On Off
ME2 K-PVW ST M/E-2 key preview output safe title on/
off
On Off
ME3 PGM1 ST
|
ME3 PGM4 ST
M/E-3 PGM1 output safe title on/off
|
M/E-3 PGM4 output safe title on/off
On Off
ME3 PVW ST M/E-3 preview output safe title on/off On Off
ME3 Clean ST M/E-3 clean output safe title on/off On Off
ME3 K-PVW ST ME-3 key preview output safe title on/
off
On Off