Chapter 16 Engineering Setup
274
Setup Relating to Operations From the Control Panel
a) For the safe title on/off commands (from ME1 PGM1 ST-ME1 PGM4 ST to AUX1 ST-AUX48
ST), the name of the assigned output signal is shown.
Assigning a menu shortcut to a memory recall button in the
utility/shotbox control block
Use the following procedure.
1
Referring to the procedure up to step 3 in the previous item, select [Menu
Shortcut].
The memory recall buttons in the utility/shotbox control block flash
orange.
2
Using any of the following methods, display the menu to which you want
to make a shortcut.
• In the menu control block, press the relevant top menu selection button,
then select VF and HF.
• Press the menu page number button in the upper left corner of the menu
screen, then enter a menu number from the numeric keypad window.
• Press a particular control panel button twice in rapid succession.
Pre Macro Set macro attachment in pre macro
mode
Can be set only
while pressed (lit)
When the function
is assigned
Post Macro Set macro attachment in post macro
mode
Can be set only
while pressed (lit)
When the function
is assigned
Macro Take Macro execution During execution When the function
is assigned
Macro Auto Ins Macro auto insert mode on/off On Off
Macro AT with Rate When registering an auto transition
macro event, on/off setting of mode to
save transition rate
On Off
Macro AT with A/B Bus When registering an auto transition
macro event for the transition control
block, on/off setting of mode to save A/
B Bus cross-point settings
On Off
Macro TL with Region When registering a timeline macro
event, on/off setting of mode to save
applicable region
On Off
DME Override DME override on/off On Off
DME Graphic DME graphics on/off (Applies to
graphics for channel selected in device
control block)
On Off
Command name
a)
Function Button status
Lit green Lit orange