Chapter 16 Engineering Setup
344
Setup Relating to Router Interface and Tally
1
In the Router/Tally>Tally Enable menu, press [New].
The New menu appears.
2
Turn the knobs to set the following parameters.
a) When you selected Group1 to 4 in the section “Setting the tally groups” (page 341), this is
1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, and 8:G4.
When you selected Group5 to 8, this is 1:R5, 2:G5, 3:R6, 4:G6, 5:R7, 6:G7, 7:R8, and
8:G8. (R is an abbreviation of “Red Tally,” and G of “Green Tally.”)
3
In the <Tally Enable> group, specify the tally generation mode.
Enable: Always generate a tally.
Disable: Never generate a tally.
Tally Input: Generate a tally from the tally input state.
4
When you selected Tally Input as the tally generation mode in step 3,
select any of the following in the <Tally Input> group.
DCU1: Generate tally with reference to signal input to DCU1 port. Set the
port number with the knob.
DCU2: Generate tally with reference to signal input to DCU2 port. Set the
port number with the knob.
5
Turn the knob to select the tally input port number.
6
Press [Execute].
This sets the settings made in steps 2 to 5 as the settings for tally
generation.
Modifying tally generation
Use the following procedure.
1
In the Router/Tally>Tally Enable menu, press [Modify].
The Modify menu appears.
Knob Parameter Adjustment Setting values
1 Destination Address Destination address 1 to 1024
2 Destination Level Destination level 1 to 8
3 Tally Type Tally type
1 to 8
a)
Knob Parameter Adjustment Setting values
5 Input No Tally input port number 1 to 102