EasyManua.ls Logo

Sony MHC-V77DW - Changing the Display Mode

Sony MHC-V77DW
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHC-V77DW
25
SECTION 4
ELECTRICAL CHECK
Procedure:
1. Turn the power on.
2. Input the following signal from Signal Generator to FM
antenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation : 75 kHz
Modulation : 1 kHz
ANT input : 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the
set. You cannot use video cable for checking.
Please use SG whose output impedance is 75 ohm.
3. Set to FM tuner function and scan the input FM signal with
automatic scanning.
4. Con rm that input Frequency of A, B and C detected and
automatic scanning stops.
The stop of automatic scanning means “The station signal is
received in good condition”.
FM AUTO STOP CHECK
signal
generator
set
+
75
TUNER SECTION
0 dB = 1 ȝV
CD/DVD SECTION
[TEST DISC LIST]
Use the following test disc on test mode.
CD: YEDS-18 (PART No. 3-702-101-01)
or
PATD-012 (PART No. 4-225-203-01)
HLX-A1 (PART No. J-2501-307-A)
• DVD (SL)
NTSC HLX-503 (PART No. J-6090-069-A)
or
HLX-504 (PART No. J-6090-088-A)
HLX-513 (PART No. J-2501-305-A)
PAL HLX-506 (PART No. J-6090-077-A)
• DVD (DL)
NTSC HLX-501 (PART No. J-6090-071-A)
or
HLX-505 (PART No. J-6090-089-A)
HLX-514 (PART No. J-2501-306-A)
PAL HLX-507 (PART No. J-6090-078-A)
Note: When the BASE UNIT is replaced, perform the Execute
IOP measurement
(Refer to page 23).
FOCUS BIAS CHECK
Procedure:
1. Connect the oscilloscope to CN302 pin 17 (RF) and CN302
pin 1 (GND) on the MOTHERBOARD board.
2. Press the [
?/1
] button to turn the power on, and press the
[FUNCTION] button to select DVD/CD function.
3. Set the test disc (CD: YEDS-18) on the tray and press [N]
button to playback.
4. Con rm that oscilloscope waveform is as shown in the gure
below (eye pattern).
A good eye pattern means that the diamond shape () in the
center of the waveform can be clearly distinguished.
+
MOTHERBOARD board
oscilloscope
(DC range)
CN302 pin 17 (RF)
CN302 pin 1 (GND)
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.1 ± 0.25 Vp-p (DVDSL)
1.0 ± 0.25 Vp-p (CD)