ICP-X7000
1-79 (E)
Procedure
1.  Open the Web menu on the NS-BUS remote control panel, and then click [Network Settings] on the 
left side of the window.
  The LAN Settings window appears.
2.  Clear the “Obtain IP address automatically (Using DHCP)” checkbox, and then make LAN1 network 
settings.
.  IP Address:   IP address of NS-BUS remote control panel (MKS-R3210/MKS-R1620)
.  Subnet Mask:   Subnet mask of NS-BUS remote control panel (MKS-R3210/MKS-R1620)
.  Default gateway:   Default gateway of NS-BUS remote control panel (MKS-R3210/MKS-R1620)
.  System Controller:   IP address of switcher control station (PWS-100SC1/PWS-110SC1)
.  NTP Server:   IP address of switcher control station (PWS-100SC1/PWS-110SC1)
3.  Click the [Apply] button.
4.  Restart the MKS-R3210/MKS-R1620.
  After restart, the set values are applied.