EasyManua.ls Logo

Sony MVS-8000 - Setting the Reference Output

Sony MVS-8000
1364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 20 Switcher Setup (Switcher)
1221
Signal Output Settings (Output Menu)
M/E-1 Output 1 to 6
a)
M/E-2 Output 1 to 6
a)
M/E-3 Output 1 to 6
a)
PGM/PST 1 to 6
a)
DME Monitor Video
DME Monitor Key
Color Corrector 1 and 2
Undefined
Color Bkgd 2
Frame Memory 1 to 8
a) M/E output signals selected in the M/E Output Assign menu.
[Aux Bus]: It is not possible to make duplicate assignments.
Preset
Edit Preview
AUX 1 to 48
3
Using any of the following methods, select the output port number and
signal to be assigned.
Press directly on the list in the status area to make the selection.
Press the arrow keys to scroll the reverse video cursor.
Turn the knobs.
For output ports not to be assigned, press [Inhibit].
The selected signal appears in reverse video.
4
Press [Set] to confirm the assignment.
Setting the Reference Output
Notes
This function is not supported on the MVS-8000G.
To adjust the reference output phase with respect to the reference input, adjust
the following parameters in the Switcher >Output menu.
Knob Parameter Adjustment Setting values
1 Output No Output port number 1 to 48
2 Source No Selection of signal to be assigned 1 and upwards
Knob Parameter Adjustment Setting values
2 Line Line phase –90 to +90

Table of Contents