Chapter 11 DME Operations
561
DME Special Effect Operations
a) Set when Lock is on.
b) Set when Lock is off.
c) Setting for SD 4:3, SD 16:9
d) Setting for HD 4:3, HD 16:9
When Angular mode is selected
a) Set when Lock is on.
b) Set when Lock is off.
When Both mode is selected
4
Speed R
b)
Ripple direction along radius
and speed
–100.00 to +100.00
5 Amp A Ripple amplitude along
periphery
0.00 to 100.00
Knob Parameter Adjustment Setting values
Knob Parameter Adjustment Setting values
1 Amp A Ripple amplitude along periphery 0.00 to 100.00
2 Freq A Ripple frequency along periphery 0.00 to 100.00
3
Offset A
a)
Direction along periphery in which
to offset ripple phase and amount
of movement
–8.000 to +8.000
4
Speed A
b)
Ripple direction along periphery
and speed
–100.00 to +100.00
5 Amp R Ripple amplitude along radius 0.00 to 100.00
Parameter group [1/2]
Knob Parameter Adjustment Setting values
1 Amp R Ripple amplitude along radius 0.00 to 100.00
2 Freq R Ripple frequency along radius 0.00 to 100.00
3
Offset R
a)
Direction along radius in which to
offset ripple phase and amount of
movement
–8.000 to +8.000
c)
–32.000 to +32.000
d)
4
Speed R
b)
Ripple direction along radius and
speed
–100.00 to +100.00
Parameter group [2/2]
Knob Parameter Adjustment Setting values
1 Amp A Ripple amplitude along periphery 0.00 to 100.00
2 Freq A Ripple frequency along periphery 0.00 to 100.00
3
Offset A
a)
Direction along periphery in
which to offset ripple phase and
amount of movement
–8.000 to +8.000
4
Speed A
b)
Ripple direction along periphery
and speed
–100.00 to +100.00