Chapter 19 Control Panel Setup (Panel)
971
Cross-Point Settings (Xpt Assign Menu)
Hold: Acts as a shift button, and the shifted version of the cross-point buttons
is enabled while the button is held down.
Lock: Acts as a shift button, and pressing the button toggles between the
shifted version and the unshifted version.
Off: Acts as a cross-point button, in a 16-button system as button number 16,
in a 24-button system as button number 24, and in a 32-button system as
button number 32.
Setting the action of the [SHIFT] button in the cross-point control
block
In the <Display Shift Mode> group of the Panel >Xpt Assign >Main, V/K Pair
Assign menu or Panel >Xpt Assign >Table Button Assign menu, select either
of the following.
Shift All Bus: When this is On, it functions as a shift button for all buses.
Key5-8 Select: This functions as a shift button dedicated to the key 1 and key
2 rows. When On, keys 5 to 8 are selected, and when Off, keys 1 to 4 are
selected.
Notes
• It is not possible to make this setting separately for each of the M/E and
PGM/PST banks.
• “Shift All Bus” is only valid when the cross-point button shift operation (see
previous item) is set to “Lock” or “Off.”
• If both Shift All Bus and Key5-8 Select are off, this button functions as a shift
button for the source name display. It is not possible to set both Shift All Bus
and Key5-8 Select to On.
Setting the source signal name
1
In the Panel >Xpt Assign menu or Panel >Xpt Assign >Table Button
Assign menu, press [Src Name/LCD Color].
The Src Name/LCD Color menu appears.
2
Turn the knob to select the signal to be set.
3
Press [Source Name].
A keyboard window appears.
Knob Parameter Adjustment Setting values
1 Source No Source signal selection 1 to 228
2 Num Number of source signals to be
selected
1 to 228