CD RF LEVEL CHECK
Connection :
Adjustment Method :
1. Set the servo mode of the test mode (Mode : 000).
2. Press the ( key, and set the CD test adjustment mode
(Mode : 050) using the VOLUME + or – key.
3. Press the = or + key and move the optical pick-up to
the center circumference.
4. Insert a test CD (TDYS-1).
5. When the ( key is pressed, the CD EF balance adjustment
mode (Mode : 052) will be set after CD focus search adjust-
ment mode (Mode : 051).
6. When the ( key is pressed, the CD ABCD level adjustment
mode (Mode : 053) is set.
7. Press the P key to perform automatic adjustment, and check
that the RF level is 1.1 ± 0.33 Vp-p.
digital voltmete