2-12
PVM-14L2/20L2
2-10. Convergence Adjustment (1)
1. Input a dot pattern signal.
CONTRAST... Conspicuous position
BRIGHT... MIN
2. Align the horizontal R, G, and B dots at the center of
the screen by adjusting RV708/C board.
* When H-CENT is changed after H-STAT adjustment,
readjust H-STAT. (H-STAT will change by means of
H-CENT VR.)
1 * After V-STAT adjustment, paint-lock the knob.
V-STAT Mg knob
While keeping the angles A and B equal (I = I’), align the
vertical convergence.
Fig. 2-14 Good example
If the A and B knobs are not symmetrical (I ≠ I’), the focus
may deteriorate, beam striking or other adverse effects may
occur.
Fig. 2-15 Bad example
I
AB
X
Y
I’
AB
X
Y
I’I
4. For HMC, use the BMC Mg to adjust the R and B dots
so that they will be symmetrical horizontally with
respect to the G dot.
Fig. 2-16
5. For VMC, use the BMC Mg to adjust the R and B dots
so that they will be symmetrical vertically with respect
to the G dot.
Fig. 2-17
6. Repeat the adjustment steps from 2 through 5.
* The above adjustment may affect the landing, so after
adjustment, check the landing again.
7. Paint-lock the knobs after adjustment.
RGB
BA
II’
6-pole magnet
AA’
Change the opening
degree of the BMC Mg
to control the HMC.
Control the BMC Mg so
that A=A’. Maintain I
=
I’
when moving the Mg.
RGB
6-pole magnet
For VMC control, turn
knob to the right or left
without changing their
opening degree of the
BMC Mg.
Make adjustment so
that the gap will be the
same at the top and bottom.
Do not change.
(Top)
(Bottom)