4-1
PVM-14L2/20L2
Section 4
Electrical Adjustments
. Digital VOM
Advantest TR6845 or equivalent
. Slide induction transformer
. High tension voltmeter
. DC power supply
. Ammeter
. Luminance meter
Minolta CRT Color Analyzer CA-100 or equivalent.
If the Minolta CRT Color Analyzer CA-100 is not
available, perform the measurement by visual inspection
by comparing the monitor that has already been adjusted
earlier with the monitor that you want to adjust.
n
Start the following adjustments 5 minutes after the main
power is turned on.
4-1. Equipment Required
. Oscilloscope
Tektronix 2465 or equivalent (with bandwidth of 350
MHz)
. NTSC/PAL component signal generator
Tektronix TG2000 +AVG1 (option module) +AWVG1
(option module) or equivalent
. Monoscope signal generator
ShibaSoku TP22AX or equivalent
. VG (programmable video signal generator)
VG854 or equivalent
. Frequency counter
Advantest TR5821AK or equivalent