3-2-2-2.
CHROMA
Leak
Adjustment
a4
Set the
CHROMA
to
“0”
using
the
PC
tools.
Connect
an
oscilloscope
to
TP302.
Adjust
the
CHROMA
PB
(A2—8A)
data
on
the
MENU
so
that
the
pedestal
portion
becomes
flat
as
shown
in
Fig.
3-6.
‘Make
flat
——__4_
Standard
value
:
0+20
mV
Fig,
3-6
Connect
an
oscilloscope
to
TP402.
Adjust
the
CHROMA
PR
(A2~89)
data
on
the
MENU
so
that
the
pedestal
portion
becomes
flat
as
shown
in
Fig.
3-7.
Make
flat
‘Standard
value
;
0
£20
mV
Fig.
3-7
3-2-2-3.
MATRIX
Adjustment
a8
2
Connect
an
oscilloscope
to
TP1251.
Adjust
the
Y
LEVEL
(A287)
data
on
the
MENU
so.
that
the
amplitude
becomes
the
standard
value
as
shown
in
Fig.
3-8,
‘Standard
value
:
A
=
540
+20
mVp-p
Fig.
3-8
Remove
the
difference
in
amplitudes
between
the
first
step
and
the
second
step
of
the
waveform
with
G-Y/B
{A2~AA)
on
the
MENU
as
shown
in
Fig.
3-9.
Remove
the
difference
in
amplitudes
between
the
second
step
and
the
third
step
of
the
waveform
with
G-
Y/R
(A2-9C)
on
the
MENU.
Repeat
the
adjustments
until
the
top
peak
of
the
waveform
becomes
flat.
G-Y/R
variable
adjustment
G-Y/B
variable
adjustment
Make
flat
0420
mV
Fig.
3-9
Connect
an
oscilloscope
to
TP1351.
Adjust
the
PB
LEVEL
(A2—E1)
data
on
the
MENU
so
that
the
first
step
and
the
fourth
step
of
the
waveform
have
the
same
amplitude
as
shown
in
Fig.
3-10.
Adjust
for
the
same
amplitude.
0
+20
mV
Fig.
3-10
Connect
an
oscilloscope
to
TP1451.