Note: All process flange nipples are 1” standard.
* Minimum 5-3/4’’ (146 mm) overhead
clearance required to remove housing cover.
** See Housing section (page 48).
*** M20 adapters are brass. Contact the factory
for alternate materials.
Chamber Dimensions
1” Connection
1-1/2” Connection
2” Connection
740 and 804 Series
Housing** W
General Purpose
Explosion Proof
Explosion Proof
Explosion Proof
N4
N7
B1
B2
1” NPT
Pneumatic P1 (3) 1/4” NPT
ATEX
Flame Proof/IS
T6
S3 w/CL
M20 x 1.5***
TestSafe
Flame Proof
S3
S8
Model
D
1, 2
E
1, 2
F
4
G H
4
I
2
L
2
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95 20-1/4 514
804 12-3/4 324 3-7/8 98 8 203 16 406 16 406 6-3/4 171 21-3/4 552
Model
D
2
E
2
F
4
G H
4
I
2
L
2
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95 20-1/4 514
804 12-7/8 327 4 102 8 203 16 406 16 406 6-3/4 171 21-3/4 552
Model
D
2
E
2
F
4
G H
4
I
2, 3
L
2, 3
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 - - - - 6 152 16 406 16 406 3-3/4
5
95
5
20-1/4
5
514
5
804 13-3/16 335 4-5/16 110 8 203 16 406 16 406 7-3/4 197 21-3/4 552
Dimensions listed are for reference only and are expressed as millimeters
over inches. (Linear = mm/in.) They are subject to change without notice.
Contact SOR for certified drawings of particular models or if special
dimensions are required.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
I
355.6
14.00
L
E
180.9
7.12
101.6
4.00
*228.6
9.00
DRAWING NUMBER
0390662
Model Name: MODEL NAME.DRAFT/1/3+
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER
VVD
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
DRAWING NUMBER REV
0390662 2
SHEET 1 OF 1
DWG SIZE
A
MODEL #
LINE ITEM #
SALES ORDER #
PURCHASE ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING
THE VERTICAL_MOUNT_ASSY AND TEXT
FILE 0390662.txt LOCATED ON THE
K:\$Engineering Services\Concept text files
THEN THE DRAWING WAS CHANGED TO
DRAFT ENTITIES.
W
W
DRAIN CONN
1"NPT OR SW
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
E
F
D
H
L
180.9
7.12
101.6
4.00
*228.6
9.00
DRAWING NUMBER
0390660
Model Name: MODEL NAME.DRAFT/2/0+
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER
VH
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
DRAWING NUMBER REV
0390660 2
SHEET 1 OF 1
DWG SIZE
A
MODEL #
LINE ITEM #
SALES ORDER #
PURCHASE ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING
THE VERTICAL_MOUNT_ASSY AND TEXT
FILE 0390660.txt LOCATED ON THE
K:\$Engineering Services\Concept text files
THEN THE DRAWING WAS CHANGED TO
DRAFT ENTITIES.
W
W
Drawing 0390660
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
F
G
L
180.9
7.12
101.6
4.00
*228.6
9.00
DRAWING NUMBER
0390661
Model Name: MODEL NAME.DRAFT/1/4+
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
MM
LINEAR =
IN
DRAWN BY
M SMITH
CHECKED BY
J REHM
ENGINEER APPROVAL
J FIFE
DATE
3/15/11
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIM DWG 200 SERIES SEALED CHAMBER
VV, VVT
EO NUMBER: 5090
SCALE: DRAWING SCALE
DO NOT SCALE PRINT
DRAWING NUMBER REV
0390661 2
SHEET 1 OF 1
DWG SIZE
A
MODEL #
LINE ITEM #
SALES ORDER #
PURCHASE ORDER #
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
REQUIRED TO REMOVE HOUSING COVER.
THIS DRAWING WAS CREATED USING
THE VERTICAL_MOUNT_ASSY AND TEXT
FILE 0390661.txt LOCATED ON THE
K:\$Engineering Services\Concept text files
THEN THE DRAWING WAS CHANGED TO
DRAFT ENTITIES.
W
W
1" SW
(VVT ONLY)
Drawing 0390661
Drawing 0390662