TUBING
Each SPA Extreme System kit is supplied with Decabon tubing which is a plastic coated
aluminum tube which can be molded and flexed to suit this application. The SPA Extreme system
has been designed and homologated using this type of tube. DO NOT substitute this tube for any
other type.
TUBE CONNECTIONS
All fittings for tube to nozzles and bottle are of the push-in type. Insert the tube into the fitting,
push firmly until it clicks. Once in you should not be able to pull it out.
To remove the tubing, push the tube into the fitting and at the same time push the black collett
back towards the fitting and then pull the tube from the fitting
MAINTENANCE
To ensure maximum possible performance from your SPA Extreme System, the following
checks and maintenance procedures should be carried out.
Regularly check pressure gauge to ensure they are in the green sector.
Regularly check nozzles for debris or any obstructions.
Regularly check the integrity of the pipework and fittings.
Regularly check the cylinder for damage.
Your SPA Extreme system must be serviced every 2 years.
A service date is written on the content label on the extinguisher. It is up to you to ensure
that the servicing is carried out at the correct intervals. Servicing of the system must be
carried out by SPA Design or Approved Vendor
If your system has been discharged, you must return it to SPA or dealers for servicing and
refilling.
NOTES
Please ensure that you monitor the following, as you
MAY NOT pass scrutineering IF: -
The needle of the gauge is in the red.
The bottle label is worn, damaged or unreadable.
The unit is not within the service date.
The system is in poor condition.