EasyManua.ls Logo

Spacelabs Healthcare 90217A User Manual

Spacelabs Healthcare 90217A
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Ambulatory Blood Pressure Monitor
90217A
070-2177-01 Rev B | www.spacelabshealthcare.com
OPERATIONS MANUAL

Questions and Answers:

Spacelabs Healthcare 90217A Specifications

General IconGeneral
Device TypeBlood Pressure Monitor
Model Number90217A
ManufacturerSpacelabs Healthcare
TypeAmbulatory Blood Pressure Monitor
Measurement MethodOscillometric
Heart Rate Range40-200 bpm
MemoryStores up to 300 readings
Data StorageInternal memory
InterfaceLCD display
Cuff SizesSmall, Medium, Large
Battery LifeApproximately 24 hours of use
Data TransferVia USB

Summary

Operation

1.1 Overview

Provides a general description of the Spacelabs Healthcare ABP monitors and their intended use.

1.1.1 ABP Monitor

Details the features and components of the 90217A ABP Monitor.

1.2 Replacing the Batteries

Instructions for replacing the main batteries in the ABP monitor.

1.3 Initializing the Monitor

Process for initializing the ABP monitor before patient monitoring.

1.3.1 Connecting Directly to a Local Report Generator

Procedure for connecting the monitor to a report generator for initialization.

1.3.2 Connecting Directly to the PC Interface

Steps to connect the monitor to a PC for initialization via software.

1.3.3 Connecting to the Base Station via Modem

Instructions for establishing a modem connection for remote initialization.

1.3.4 Modem Speed and Compatibility Issues

Information on modem compatibility and connection procedures.

1.3.5 Office Check Mode

Details the monitor's automatic Office Check mode after initialization.

1.4 Preparing the Patient and Precautions for Use

Guidance on patient preparation and initial safety precautions.

1.4.1 Using Cuff Support

Instructions for properly using the cuff support accessory.

1.4.2 Optional Accessories

Lists available optional accessories for the ABP monitor.

1.4.3 Correlating with Manual Readings

Method for correlating monitor readings with manual auscultatory measurements.

1.4.4 Patient Instructions

Guidance for patients on using the monitor and handling common issues.

1.5 Data Transfer and Reports

Procedures for transferring data and generating reports from the monitor.

1.6 Cleaning/Disinfecting

Instructions for cleaning and disinfecting the ABP monitor and its components.

1.6.1 Cleaning the Cuff and Carrying Pouch

Specific steps for cleaning the cuff wrap and carrying pouch.

1.6.2 Removing/Installing the Bladder

Procedure for removing and reinstalling the bladder from the cuff.

1.7 Event Codes

Explanation of event codes displayed by the monitor and their meanings.

Accuracy

2.1 Checking Accuracy

Overview of the procedure for checking the accuracy of the ABP device.

2.1.1 Accuracy Procedure

Step-by-step guide for performing the accuracy check on the monitor.

Technical Data

3.1 90217A Ultralite ABP Monitor

Detailed specifications for the 90217A Ultralite ABP Monitor.

3.1.2 Features, Controls, Connectors and Indicators

Description of the monitor's features, controls, connectors, and indicators.

3.1.3 General

General technical specifications and measurement ranges of the monitor.

3.1.4 Patient Safety

Information regarding patient safety mechanisms and requirements.

3.1.5 Electrical Requirements

Details on the power source and electrical specifications for the monitor.

3.1.6 Physical Dimensions

Specifications for the physical size and weight of the ABP monitor.

3.1.7 Environmental Requirements

Operating and storage conditions for the ABP monitor.

3.2 Electromagnetic Compatibility

Information on the monitor's compliance with electromagnetic compatibility standards.

3.2.1 General notes

General notes regarding the monitor's electromagnetic compatibility.

3.2.2 Guidance and manufacturer's declaration – electromagnetic emissions

Declaration regarding electromagnetic emissions from the monitor.

3.2.3 Guidance and manufacturer's declaration – electromagnetic immunity

Declaration regarding electromagnetic immunity of the monitor.

3.2.4 Guidance and manufacturer's declaration – electromagnetic immunity

Further guidance on electromagnetic immunity for the monitor.

Troubleshooting

4.1 Problem Solving Checklist

A checklist of common problems, their possible causes, and solutions.

4.2 Servicing

Information on product servicing, warranty, and repair procedures.

Appendix - Signs and Symbols

General Safety

Explanation of general safety symbols used on Spacelabs Healthcare products.

General Use

Explanation of symbols related to general operation and controls.

Frequently Used Functions

Icons representing frequently used functions and connections.

Packaging

Symbols related to packaging, shipping, and handling.

Certification and Compliance

Details on product certifications and regulatory compliance.

Manufacturer Information and Traceability

Information on the manufacturer, lot number, and serial number.

Notations and Abbreviations

Definitions of abbreviations and symbols used in the manual.

Related product manuals