Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 30 P/N 79000035_SM, Version 1.5
Sensor specific messages Subsystem: FI_DARWIN_Tilt
General status combined from communication status 1 - 6 and sensor specific messages A - D:
Unknown
Ok
Not communicating...
Not initialized...
Not active...
Timeout warning
Failed warning
Reading time out
Not enough readings
03 Subsystem error:Angle V
V-Angle sensor not
communicating 1 2 3 4 A A1
Drive system Turn event
error warning 6 B D1
FI: 10 Code: 0xf005
Message: 3|0|99|200|-
24567300|PositionHV faile
Error: 0xf004
FI: 1 Code: 0x9c4e Message:
V-Angle sensor: Not
communicating ( 1 2 3 4
FI: 1 Code: 0x9c4e Message:
Drive system: Turn event
error warn. ( 6 B D
Check the cable V-ACB.
04 V-angle measurement failed
(after turning telescope)
readings disturbed C D (dirt
spots)
Drive system Error msg
warning 6 or Turns blocked 6
D D1
FI: 10 Code: 0xf002
Message: Angle
measurement failed
FI: 25 Code: 0x9c54
Message: Angle
measurement faile
FI: 10 Code: 0xf005
Message: 2|0|99|158236400|-
107579800|PositionHV faile
0x9c4e Message: V-Angle
sensor: Readings disturbed (
C D
Clean the V-glass circle.
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation

Table of Contents