Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 32 P/N 79000035_SM, Version 1.5
Not enough turns
Target not locked
Sensor specific messages Subsystem: FI_Darwin_Drives
Performance
Value Value description Status Ok Counter Error Counter
A Position HV Response Ok IM presets H/V
position, where to drive.
10- Ok status
1- Error message
B Position HV event Ok H/V position reached
and positive event to IM.
10- Ok status
1- Error message
C Target Ok Tracker has locked to
target.
10- Ok status
1- Error message
Additional results
perfoming a
Diagnostics:
D1 Could NOT turn 4
times complete to
position.
C1 Could NOT lock with
Tracker to prism
target.
Value Blocked Unblocked Pos-
Reached
Stopped Failure
Notifications 0 0 010
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation
1 Subsystem error drives
Drive system not initialied 2
3 6 B D D1
FI: 10 Code: 0xf005
Message:
3|0|99|0|1104500|PositionHV
faile
FI: 10 Code: 0x9c52
Message: Req x6e got res 9
FI: 1 Code: 0x9c4e Message:
Drive system: Not initialized
( 2 3 6 B D
Check Fine drive vertical
Exchange the Fine drive
vertical