Summary

WELCOME TO YOUR SPECTRA S9+

Features

Key features of the Spectra S9+ personal double electric breast pump.

General Safety Guidelines

Essential safety precautions for using the breast pump correctly.

IMPORTANT SAFEGUARDS

Critical instructions to prevent damage or injury when using the pump.

INCLUDED WITH YOUR SPECTRA S9+

Pump Components Overview

Visual and textual identification of all included pump parts.

Initial Sterilization Advice

Instructions for sterilizing parts before first use, specifying what not to sterilize.

QUICK START GUIDE

Initial Setup and Assembly

Steps for sterilizing parts, assembling the kit, and attaching tubing.

Achieving Optimal Fit and Settings

Guidance on breastshield fit and adjusting massage/expression modes.

Pumping Tips for Success

Advice on relaxation, hydration, and techniques to improve milk expression.

ASSEMBLING YOUR MILK COLLECTION KIT

Note on Spectra Valves

Information regarding the interchangeability of different Spectra valve types.

ASSEMBLING YOUR SPECTRA S9+

Tubing and Collection Kit Assembly

Instructions for connecting tubing and assembling the milk collection kit.

Pumping Configuration

Steps for setting up the pump for single or double pumping.

Connecting Power and Charging

Guidance on attaching the power adapter and charging the pump.

PUMPING INSTRUCTIONS

Modes and Settings Adjustment

How to use massage/expression modes and adjust vacuum strength.

Timer Functionality

Information on the automatic shut-off timer and how it resets.

BREASTSHIELD SIZING GUIDE

Signs of Too Small Breastshield

Indicators that the breastshield may be too small, causing discomfort or poor output.

Signs of Too Large Breastshield

Indicators that the breastshield may be too large, affecting comfort and efficiency.

Advanced Shield Sizing Tips

Additional advice and factors to consider for accurate breastshield sizing.

CLEANING & STERILISATION

Initial Sterilization Procedures

How to sterilize parts before first use, including boiling water method.

Alternative Methods & Precautions

Information on other sterilization methods and important precautions.

CLEAN YOUR PARTS DAILY

Parts Requiring Daily Cleaning

Identifies which pump parts need cleaning after each use.

Hand Washing Procedure

Detailed steps for washing pump parts manually with soap and water.

Dishwasher Cleaning Method

Instructions for safely cleaning pump parts using a dishwasher.

TIPS FOR EXPRESSING BREASTMILK

Optimizing Pumping Environment and Routine

Tips on relaxation, hydration, environment, and establishing pumping routines.

Techniques for Milk Flow and Comfort

Advice on stimulating milk flow, managing discomfort, and pumping frequency.

BREASTMILK STORAGE

Storing Freshly Expressed Milk

Recommended storage durations for milk at room temperature, cooler, and refrigerator.

Thawing Frozen Breastmilk

Instructions for safely thawing breastmilk that has been frozen.

Storing Milk After Feeding

Guidelines for storing breastmilk after it has been offered to the baby.

BREASTMILK STORAGE (CONTINUED)

Storing Previously Stored Milk

Storage times for milk that was previously refrigerated or frozen after feeding.

Freezer Storage Guidelines

Recommended storage durations for breastmilk in different types of freezers.

TROUBLESHOOTING

Pump Power and Suction Issues

Solutions for the pump not turning on or experiencing low/no suction.

Assembly and Component Problems

Troubleshooting for backflow protectors, tubing, leaks, and assembly errors.

Pumping Performance Issues

Addressing problems like one-sided pumping or internal tubing detachment.

CARING FOR YOUR SPECTRA S9+

Replacing Pump Parts

Recommended replacement schedule for pump components to ensure optimal performance.

Warranty and Repair Services

Information on product warranty coverage and how to access repair services.

Product Disposal Guidelines

Instructions for the responsible disposal and recycling of the breast pump.

TECHNICAL SPECIFICATIONS

Performance Specifications

Key performance metrics including vacuum strength, cycle speeds, and battery life.

Physical and Warranty Details

Information on pump weight, motor life, warranty period, and country of origin.

Environmental and Safety Compliance

Details on electromagnetic compatibility and environmental operating conditions.

Overview

The Spectra S9+ is a personal double electric breast pump designed to help mothers express breast milk efficiently and comfortably. It is a portable and stylish device, making it convenient for use at home or on the go. The pump is designed to mimic a baby's natural suckling, offering both massage and expression modes to optimize milk flow and comfort.

Function Description

The primary function of the Spectra S9+ is to extract breast milk from the user's breasts. It operates with two distinct modes: Massage Mode and Expression Mode.

  • Massage Mode: This mode is designed to stimulate letdown, mimicking the fast, fluttering suckling a baby performs at the beginning of a feed. It uses a fast cycle speed (70 CPM) and adjustable vacuum strength (levels 1-5) to encourage milk flow. Users are advised to start in this mode to trigger milk ejection.
  • Expression Mode: Once milk flow is established, users can switch to Expression Mode. This mode mimics the slower, steady suck-and-swallow rhythm of a baby during active feeding. It features a slower cycle speed and a wider range of adjustable vacuum strength (levels 1-10) to optimize milk expression.

The pump is capable of both single and double pumping. Double pumping allows for simultaneous expression from both breasts, which can save time and potentially increase milk supply. The device includes two sets of tubing, backflow protectors, breastshields, duck valves, and bottle kits to facilitate double pumping.

A key feature of the Spectra S9+ is its closed system, which incorporates backflow protectors. These protectors prevent milk from flowing back into the pump motor or tubing, ensuring hygiene and preventing contamination. This design helps protect the motor from moisture and milk, which could otherwise lead to mold or bacteria growth.

The pump is powered by a rechargeable Li-Polymer battery, offering portability and the ability to pump without being tethered to a power outlet. It can also be used while plugged into mains power. An LCD screen with a backlight provides clear visibility of settings, including timer, vacuum level, and mode, even in low-light conditions.

Usage Features

The Spectra S9+ is designed for user-friendliness and comfort.

  • Adjustable Vacuum Levels: Both Massage and Expression modes offer adjustable vacuum strengths. Users are encouraged to find a comfort level that is effective for milk expression without causing pain. Starting with a low vacuum and gradually increasing it is recommended.
  • Letdown Mode (Massage Mode): The pump automatically starts in Massage Mode, which is crucial for initiating letdown. Users can switch to Expression Mode once milk starts flowing.
  • Fully Adjustable Vacuum Settings: The touch button controls allow for easy adjustment of vacuum levels, ensuring a personalized and comfortable pumping experience.
  • Backlit Screen: The S9+'s backlit screen makes it easy to monitor pumping settings and time, even in dimly lit environments, which can be beneficial during night pumping sessions.
  • Portable Design: Its compact and lightweight design makes it easy to carry and use anywhere. The rechargeable battery further enhances its portability.
  • Timer: A built-in timer tracks the duration of each pumping session, automatically powering off after 30 minutes. This helps users maintain consistent pumping schedules.
  • Breastshield Sizing: The pump comes with 24mm breastshields, but the manual emphasizes the importance of proper breastshield sizing for comfort and optimal milk output. It provides detailed guidance on how to measure nipple diameter after pumping and identify signs of incorrect shield sizing (too small or too large). Users are advised to measure their nipples after they have swollen from pumping and select a shield size 2-3mm larger than the measured diameter.
  • Pumping Tips: The manual offers practical advice for effective pumping, including staying hydrated, creating a relaxing environment, establishing a routine, visualizing milk flow, using baby's scent or cry to trigger letdown, massaging breasts before and during pumping, increasing pumping frequency, pumping on a schedule, and using hands-free solutions. It also strongly advises against pushing through pain during pumping.

Maintenance Features

Proper cleaning and maintenance are essential for the longevity and hygienic operation of the Spectra S9+.

  • Sterilization Before First Use: All parts that come into contact with breast milk (bottles, breastshields, valves, backflow protectors, bottle necks, sealing discs, caps, and teats) must be sterilized before their first use. The manual provides instructions for boiling water sterilization, recommending a 5-minute boil. It also mentions other methods like microwave steam sterilizers and chemical solutions, advising users to follow manufacturer instructions for these.
  • Daily Cleaning: After each use, all parts that come into contact with breast milk should be cleaned. The manual clarifies that daily cleaning is usually sufficient, and parts can be stored in a sealed container in the refrigerator between uses.
  • Hand Washing: Detailed instructions for hand washing parts are provided, emphasizing the use of potable water, dish soap, a dedicated wash basin, and a sponge or bottle brush. Parts should be fully disassembled, washed thoroughly, rinsed, and air-dried on a clean paper towel.
  • Dishwasher Washing: Breast pump parts can be washed on the top rack of a dishwasher using a normal dishwashing setting. It is crucial to use an air-dry setting, not heat dry, to prevent warping. Delicate parts like valves and membranes are best hand-washed.
  • Tubing Care: A critical maintenance point is to never wash the tubing or allow it to get wet. The backflow protectors prevent milk from entering the tubing, and moisture in the tubing can lead to mold or bacteria growth, rendering it unhygienic and requiring replacement. Backflow protectors themselves only need cleaning if milk or moisture is visible inside them.
  • Regular Part Replacement: To maintain optimal pump performance and prevent unnecessary wear on the motor, certain parts need to be replaced regularly:
    • Valve Membrane: Every 2-8 weeks, or when a decrease in suction is noticed.
    • Duck Valve: Every 2-3 months, or when a decrease in suction is noticed.
    • Backflow Protector: Every 3-6 months.
    • Breastshield: Every 6 months.
    • Tubing: Immediately if moisture enters it.
  • Disposal: The manual provides guidelines for the disposal of pump components. Milk collection kits and other breast pump accessories are for single-person use and should not be reused second-hand. Hard plastic parts like breastshields and bottles can typically be recycled, while silicone parts (duck valves, membranes, tubing, teats) must be thrown away. The pump motor and adaptor should be disposed of at a designated electronics recycling location, in compliance with EU Directive 2002/96/EC (WEEE).
  • Warranty and Repair: The product comes with a 2-year warranty covering defects in material and workmanship. The warranty does not cover damage from misuse or improper maintenance. Information on warranty claims, service, and repair is provided, directing users to contact customer support or visit the website.

Spectra S9+ Specifications

General IconGeneral
TypeElectric Breast Pump
Noise Level45 dB
Pump TypeDouble Electric Breast Pump
Hospital GradeNo
Letdown ModeYes
TimerYes
Cycle SpeedsAdjustable
Battery LifeUp to 3 hours
Memory FunctionYes
Closed SystemYes
BatteryRechargeable lithium-ion battery
DisplayLCD
ModesMassage and Expression
Suction Levels12
Suction Strength260 mmHg
Power SourceBattery or AC adapter
Charging Time4 hours
PortabilityYes
Included AccessoriesFlanges, tubing, bottles, AC adapter