FATC
ACTYON 2008.01
0000-00
3) Set in Trouble Diagnosis Step 3
In this step, check the position and conditions of recirculation air door and mode door.
Slightly turn the TEMP switch until "3" is displayed on the display window.
If no failure exists, "30" is displayed. If any failure exists, the appropriate trouble code is
displayed.
Slightly turn the TEMP dial to the right to set in the trouble diagnosis step 3
Indication of Step 2.
Starting self diagnosis
Sensor failure code
blinking (30: no failure)
Trouble Code
4) Set in Trouble Diagnosis Step 4
In this step, check the position of actuator door, check the fan speed, and check the
compressor operation.
Slightly turn the TEMP switch in step 3 until "41" is displayed on the display window. When
pressing DEF switch , mode changes as shown below in turns to check each function.
Slightly turn the TEMP dial to the right
to set in the trouble diagnosis step 4