19
4 In-Home: Video users
Switching, control
BSM 650-02
Bus switching module in 3-grid
housing. 4 integrated relays, each
with a potential-free working con-
tact. Actuation via the call buttons
of the bus telephones or light button
at the door station. Relay functions
as a timer between 0.4 seconds
and 12 seconds. Max. contact load
15 V AC, 30 V DC, 2 A. 12 V AC
supply required, 250 mA.
BIM 650-02
Bus interface module in switch
panel housing, used for connection
between Siedle Vario bus and Siedle
In-Home bus.
It is always required when a bus
door oudspeaker has to be equipped
with a COM 611-... or DRM 611-...
and call controller RC 602-... in
addition to or instead of direct call
buttons.
BSE 650-0
Bus switching unit for mounting in
70 mm boxes. LED for status display
and programming mode button.
Actuation via the call buttons of the
bus telephones or light button at the
door station. The relay functions as a
button, switch or timer for max.
19 min. 59 secs. Max. contact load
250 V AC / 6 A.
BVD 650-0
The bus video demodulator in a
6-grid switch panel housing converts
the video image at the bus cores
of the In-Home bus: video into a
standard FBAS video signal.
The converted video image can
subsequently be transmitted to any
video monitor or any TV with a suit-
able input or can be further
processed in a video system.
BEM 650-0
Bus input module for mounting in
a 55 junction box with an input for
tripping switching functions/trans-
mitting messages at the In-Home
bus.
Activation possible via potential-free
contact or 4 - 30 V DC, 10 mA.
For connection of BSM 650-...,
BSE 650-... and BEM 650-... to the
In-Home bus: Video,
the BAA 650-... is required.