29
AS-TVHa-1/1 Siedle Vario with
S 850-0
Mode of operation
Calling, speech and video between
the door station and the connected
bus telephones BTSV/BFSV/BTCV/
BFCV 850-... or S 850-0 with colour
monitor.
An existing call can not be listened
in to or viewed by other bus tel-
ephones. Door release button for
the door release function, light
button for the light switching func-
tion. Pressing the monitor button
will show the camera picture from
the door station which placed the
last door call. This function is only
possible if no call exists.
Connection of a storey call button
(ERT) for calling from an apartment
door. Ring tones can be selected for
calls from the front door, apartment
door or internal calls.
If more than one S 850-0 or other
bus telephones with colour monitor
are installed in a system, a
BVVU 650-0 is required for each
S 850-0.
Other bus door loudspeakers with
video are connected with bus
video distributors BVVU 650-... or
BVVS 650-... .
Supplementary functions
• Internal speech communication
possible between bus telephones
BTSV/BFSV/BTCV/BFCV 850-0 or
S 850-0 .
• Connection of bus telephones
BTS/BFS/BTC/BFC 850-... or devices
for switching and control functions
via bus audio decoupler BAA 650-...
For more information, see chapter 6,
page 54-55.
• Switching and control func-
tions possible with bus switching
modules BSM 650-..., BSE 650-...
and BEM 650-... , feedback to bus
telephones BTC/BFC/BTCV/
BFCV 850-... programmable via LED.
For more information, see chapter 8,
page 89-91.
• Bus secondary signal unit
BNS 750-... possible, chapter 8,
page 96.
• Parallel door and storey call
Up to 8 bus telephones with colour
monitor can be called simultaneously
via one call button. From the second
bus telephone, each bus telephone
must be additionally supplied at the
terminals +M/-M.
• Selective dialling of the door
station
possible via additional free buttons.
Remarks
a) The TR 603-... (12 V AC, 1.3 A)
can supply 1 door release button
and max. 24 bus call button mod-
ules with LED lighting (BTM 650-01,
-02, -03 and -04).
With more than 24 illuminated bus
call button modules, an additional
TR 603-... is required.
Current consumers in the AS dia-
gram:
Door release appr. 600 mA
Camera heating 100 mA
LED lighting per bus call button
module 20 mA
b) Door release contact load in the
bus video line rectier BVNG 650-...
max. 15 V AC, 30 V DC, 2 A.
• Light contact load in the bus video
line rectier max. 15 V AC, 30 V DC,
2 A.
In-Home-Bus: Video
TaE
3
TaD
TaA 1
TbE
4
TbD
TbA 2
ERT
BVVU 650-...
f)
In-Home
Device
requirement
Remarks
Junction box
UAE 8 (8)
c) Door release 12 V AC, use at
least 20 Ohm, (e.g. TÖ 615-...), for
possible connection variants see
chapter 8, page 92.
d) Conductor length bus telephone -
storey call button ERT max. 50 m.
e) If more than one S 850-0 or other
bus telephones with colour monitor
are installed in a system, a
BVVU 650-0 is required for each
S 850-0.
f) If several BVVU 650-...units are
switched in series, the combination
of resistor and capacitor at TaD, TbD
must be removed.