RM0046 FlexPWM
Doc ID 16912 Rev 5 669/936
Table 356. DTSRCSEL field descriptions
Field Description
1:0
SELA_3
PWMA_3 Control Select
This field selects possible over-rides to the generated PWMA signal in submodule 3 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMA_3 signal is used by the deadtime logic.
01 Inverted generated PWMA_3 signal is used by the deadtime logic.
10 OUTA_3 bit is used by the deadtime logic.
11 Reserved
2:3
SELB_3
PWMB_3 Control Select
This field selects possible over-rides to the generated PWMB signal in submodule 3 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMB_3 signal is used by the deadtime logic.
01 Inverted generated PWMB_3 signal is used by the deadtime logic.
10 OUTB_3 bit is used by the deadtime logic.
11 Reserved
4:5
SELA_2
PWMA_2 Control Select
This field selects possible over-rides to the generated PWMA signal in submodule 2 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMA_2 signal is used by the deadtime logic.
01 Inverted generated PWMA_2 signal is used by the deadtime logic.
10 OUTA_2 bit is used by the deadtime logic.
11 Reserved
6:7
SELB_2
PWMB_2 Control Select
This field selects possible over-rides to the generated PWMB signal in submodule 2 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMB_2 signal is used by the deadtime logic.
01 Inverted generated PWMB_2 signal is used by the deadtime logic.
10 OUTB_2 bit is used by the deadtime logic.
11 Reserved
8:9
SELA_1
PWMA_1 Control Select
This field selects possible over-rides to the generated PWMA signal in submodule 1 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMA_1 signal is used by the deadtime logic.
01 Inverted generated PWMA_1 signal is used by the deadtime logic.
10 OUTA_1 bit is used by the deadtime logic.
11 Reserved
10:11
SELB_1
PWMB_1 Control Select
This field selects possible over-rides to the generated PWMB signal in submodule 1 that will be
passed to the deadtime logic upon the occurrence of a “Force Out” event in that submodule.
00 Generated PWMB_1 signal is used by the deadtime logic.
01 Inverted generated PWMB_1 signal is used by the deadtime logic.
10 OUTB_1 bit is used by the deadtime logic.
11 Reserved